60Ah Lithium Battery, 3.2V 3C (10C peak, 10 sec)
Aluminum Shell Batteries
Lithium LiFePO4
5.4L * 1.6W * 8.3H in
137 * 40 * 211 mm
3.7 Lbs. / 1.7 Kg
Threaded posts are M10 (.39 inches)
*Currently in our Stock (USA)*
*International Stock/Production Available (no minimum quantity)*
HOW-TO VIDEOS FOR FORTUNE BATTERIES
NOTE: The batteries do not ship with threaded rods.
Two standard and one non-standard busbars per cell are included in the price. Please state the number of parallel batteries in the circuit with your order.
Example:
8 Batteries in series will be written as "8S".
4 Parrallel strings of batteries will be written as "4P".
So a 24 Volt 400Ah matrix will be written as "8S4P".
Note: All Fortune cells are warrantied for up to two years when operated with a commercially available Battery Management System ‘BMS’ and recharged with a charging system designed to recharge LiFePO4 batteries.
Quantity
Ship from Salt Lake City Stock
96+
$71.00
48-95
$73.00
24-47
$75.00
16-23
$78.00
5-15
$81.00
1-4
$85.00
60Ah Battery
Shipping Estimate
4
8
16
Zone
1
$100.00
$220.00
2
$80.00
$110.00
$230.00
3
$120.00
$240.00
$90.00
$130.00
$260.00
5
$95.00
$140.00
$280.00
Specifications:
NOMINAL/MINIMUM CAPACITY
60Ah @ 1/3C Discharge
MAX DISCHARGE CURRENT (continuous)
180A (<3C)
STANDARD CHARGE CURRENT
30A (0.5C)
MAX PULSE CHARGE CURRENT (<10 sec)
600A (10C)
MAX PULSE DISCHARGE CURRENT (<10 sec)
600A
CURRENT RATING OF BUSBARS
150A
NOMINAL VOLTAGE
3.2
SUGGESTED MAX CHARGE VOLTAGE
3.65
END OF DISCHARGE VOLTAGE
2.2
CYCLE LIFE AT STANDARD (80%)
>3000
INTERNAL RESISTANCE/IMPEDANCE (milliohms)
0.8
SUGGESTED CHARGING CURVE
Constant Amperage to 3.65V,
Constant Voltage,
Decrease Amperage,
Stop at 1A Charge
CHARGE WORKING TEMP F (C)
32 to 122 (0 to 50)
DISCHARGE WORKING TEMP F (C)
-4 to 122 (-20 to 50)
STORAGE TEMP F (C)
14 to 113 (-10 to 45)
ENERGY TYPE
3V-3.2V-3.65V,
60Ah Lithium, LiFePO4,
LFP Aluminum
Shell Battery
Connect your new 60Ah lithium, LiFePO4, LFP aluminum shell battery pack together in parallel (neg to neg and pos to pos) for more than 8 hours before connecting in series and charging. This gives your new batteries time to balance their voltages.
It is also strongly suggested that you use a BMS or balancing system.
Always use caution when working with high voltages.